Standard cubic feet per minute (SCFM) is a volumetric flow-rate corrected to a set of "standardized" conditions of pressure, temperature, and relative humidity. Ratings found in centrifugal fan performance tables and curves are based on standard cubic feet per minute (SCFM). To move air, either a positive pressure or a vacuum must be created. This cubic feet per minute conversion calculator helps you calculate either of the three namely, the air flow in FPM (Feet per Minute), CFM (Cubic Feet per Minute) and Area in square feet. The volume of gas after it is pressurized or rarefied is referred to as its "actual" volume. Use the below calculator to find the value of air flow in FPM or CFM. It is commonly used by manufacturers of blowers and compressors.This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation. Thousands of units, and millions of conversions.

The purpose of AMCA Standard 210 is to define exact procedures and conditions of fan testing so that ratings provided by various manufacturers are on the same basis and may be compared. The standard conditions are often defined as 14.7 psia, temperature 70°F and relative humidity 0%, but the conditions may vary depending on the "standard" used. Use this online Physics conversion CFM calculator to calculate the air flow of a pipe. If the system were moving air at exactly the "standard" condition, then ACFM would equal Standard cubic feet per minute (SCFM). Select the unit to convert to in the output units list. Centrifugal fans that are specified for continuous operation at higher temperatures need to be selected taking into account air density corrections. eFunda provides extensive Unit Conversion, Equations, and Material Data of value to engineers. Most Popular Conversion Pages. Get more information and details on the 'cfm' measurement unit, including its symbol, category, and common conversions from cfm to other volume flow rate units.

The cubic feet per minute (CFM) is a unit of volumetric flow. Using the airflow calculator above, type the airflow value of 400 and select LFM as the units. Actual cubic feet per minute is the volume of gas and air flowing anywhere in a system independent of its density.
Centrifugal fans rated by the Air Movement and Control Association (AMCA) are tested in laboratories with test setups that simulate installations that are typical for that type of fan. Actual cubic feet per minute (ACFM) is a unit of volumetric flow. Select the unit to convert from in the input units list. When the centrifugal fan performance is not at standard conditions, the performance must be converted to standard conditions before entering the performance tables. Next type the circular duct dimensions of r = 2 in. To get the actual horsepower at 200°F, the designer would have to multiply the brake horsepower at standard conditions by the air density correction factor. This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation. Air velocity (distance traveled per unit of time) is usually expressed in Linear Feet per Minute (LFM).


Information: "-force" is added to distinguish units of force from units of mass. Cubic Feet Per Minute (cfm) and Cubic Meter Per Hour (cmh) are the units of volumetric capacity. Normal cubic feet per minute (NCFM) refers to air at normal conditions, such as 14.7 psia, 68°F, 36% relative humidity. Air flow is calculated in either Cubic Feet per Minute (CFM) or Feet per Minute (FPM). Air Movement and Control Association fan rating, Learn how and when to remove this template message, Standard conditions for temperature and pressure, ACFM versus SCFM for ASME AG-1 HEPA Filters. It is calculated in either Cubic Feet per Minute (CFM) or Feet per Minute (FPM).

If, for example, a centrifugal fan moves 1,000 CFM at 70°F it will also move 1,000 CFM at 200°F. The site also includes a predictive tool that suggests possible conversions based on input, allowing for easier navigation while learning more about various unit … Next type the circular duct dimensions of r = 2 in. When a centrifugal fan is specified for a given CFM and static pressure at conditions other than standard, an air density correction factor must be applied to select the proper size fan to meet the new condition.